Home » News center » Flexible overhead contact system-Other parts
Flexible overhead contact system-Other parts
      Promulgator :LX      Time:2019-03-25

Overhead crossing
       To fix two contact wire at two contact suspension at point


NOS/N
Item
Unit
Index
1
Sliding load between steady clamp and contact wire
kN
≥1.5
2
Deflection of limit tube
mm
Max vertical work load of overhead crossing center: 0.18 kN. Deflection of limit tube shall not more than 1.5%L.

Connection clamp for messenger wire
       Used for installed at the messenger wire, to connect two adjacent messenger wire.


NOS/N
Item
Unit
Index
1
Max work load
kN
14.6
2
Slide load between this components and messenger wire
kN
≥40
3
The continuous carrying current capacity
A
≥ 540
4
The carrying current capacity in 5 minutes
A
≥ 760
5
contact resistance
Ω
≤ 1.4*10 -5

Connection clamp for contact wire 
      Used for installed at the contact wire point, to connect two adjacent contact wire


NOS/N
Item
Unit
Index
1
Max work load
kN
17.3
2
Slide load between this components and contact wire
kN
≥40
3
The continuous carrying current capacity
A
≥ 540
4
The carrying current capacity in 5 minutes
A
≥ 760
5
contact resistance
Ω
≤ 1.4*10 -5

Fitting for additive wire
Ⅰ)Socket end clamp
      It is used for suspend metal wire ofφ9~20 In electric railway


NOS/N
Item
Unit
Index
1
Max work load
kN
4.9
2
Failure load
kN
≥ 14.7
3
Sliding load
kN
≥ 3.9

Ⅱ)Hook end clamp
      It is used for suspend metal wire ofφ9~22 in electric railway


NOS/N
Item
Unit
Index
1
Max work load
kN
4.9
2
Failure load
kN
≥ 14.7
3
Sliding load
kN
≥ 3.9

Ⅲ)Three feeder wires clamp
      It is applied to installing three branch feeder wire TJ150


NOS/N
Item
Unit
Index
1
Sliding load
kN
≥ 2
 
No comment
Total 0 records, divided into1 pages. First Prev Next Last