Home » News center » Rigid suspension parts
Rigid suspension parts
      Promulgator :LX      Time:2019-03-25
Rigid suspension parts

Steady clamp for aluminum profile
       Steady clamp for aluminum profile is used for vertical suspension installation of rigid suspension aluminum profile . Thereinto, type C and W is for cantilever structure.




 

NO
Item
Unit
Index
1
Max. vertical work load
kN
3.0
2
Max. level work load
kN
1.5

Rigid suspension parts(2)

Spring steady clamp
       Spring steady clamp is applicable to 120 Km/h rigid suspended the converge-wires installation of vertical suspension


 

NO
Item
Unit
Index
1
Max. vertical work load
kN
3.0
2
vertical failure load
kN
9.0
3
Max. level work load
kN
1.5
4
level failure load
kN
4.5
5
Spring when spring is deformed 1.5mm
kN
0.1

Rigid suspension parts(3)
Mid-anchor clamp
      Mid-anchor clamp for aluminum profile is used for mid anchor of rigid suspension aluminum profile anchor section.



NO
Item
Unit
Index
1
Max. vertical work loadr
kN
3.0
2
slide load
kN
8.0


NO
Item
Unit
Index
1
Max. vertical work loadr
kN
3.0
2
slide load
kN
4.0

Rigid suspension parts(4)
Electrical connecting clamp for aluminum profile
      Electrical connecting clamp for aluminum profile is used for electrical continuously for each anchor section of rigid suspension aluminum profile anchor section.


 

NO
Item
Unit
Index
1
Continuous current carrying capacity
A
1800
2
Min slide load
kN
≥2.0
3
Contact resistance
Ω
≤0.000014

Rigid suspension parts(5)
Earthing clamp for aluminum profile
      Earthing clamp for aluminum profile is used for earthing protection of rigid suspension aluminum profile .


 

NO
Item
Unit
Index
1
Min slide load
kN
≥2.0

Rigid suspension parts(6)
Mid-anchor insulator
      Mid-anchor insulator is used for insulation installation of rigid suspension mid-anchor inside tunnel.


 

NO
Item
Unit
Index
1
Power frequency dry enduring voltage at 1min.
kV
≥60
2
Power frequency wet enduring voltage at 1 min
kV
≥30
3
Thunder full wave impact enduring voltage
kV
≥125
4
Mini tensile failure load
kN
≥70

Rigid suspension parts(7)
Insulation lateral braces
      The parts is used for rigid suspension low clearance line of line section inside tunnel



NO
Item
Unit
Index
1
Power frequency dry withstand voltage at 1min
kV
≥60
2
Power frequency wet withstand voltage at 1 min
kV
≥30
3
Pollution withstand voltage
kV
≥4
4
Mini creepage distance
mm
≥250
5
Mini tensile failure load
kV
≥70

 
No comment
Total 0 records, divided into1 pages. First Prev Next Last